APC APDU10450ME unité de distribution d'énergie 48 sortie(s) CA 0U Noir
search
  • APC APDU10450ME unité de distribution d'énergie 48 sortie(s) CA 0U Noir
  • APC APDU10450ME unité de distribution d'énergie 48 sortie(s) CA 0U Noir
  • APC APDU10450ME unité de distribution d'énergie 48 sortie(s) CA 0U Noir
  • APC APDU10450ME unité de distribution d'énergie 48 sortie(s) CA 0U Noir
  • APC APDU10450ME unité de distribution d'énergie 48 sortie(s) CA 0U Noir
  • APC APDU10450ME unité de distribution d'énergie 48 sortie(s) CA 0U Noir
  • APC APDU10450ME unité de distribution d'énergie 48 sortie(s) CA 0U Noir
  • APC APDU10450ME unité de distribution d'énergie 48 sortie(s) CA 0U Noir
  • APC APDU10450ME unité de distribution d'énergie 48 sortie(s) CA 0U Noir
  • APC APDU10450ME unité de distribution d'énergie 48 sortie(s) CA 0U Noir
  • APC APDU10450ME unité de distribution d'énergie 48 sortie(s) CA 0U Noir
  • APC APDU10450ME unité de distribution d'énergie 48 sortie(s) CA 0U Noir

APC APDU10450ME unité de distribution d'énergie 48 sortie(s) CA 0U Noir

3 100,00 €
TTC
APC APDU10450ME, Commutable, 0U, Monophasé, verticale, Noir, LCD
Quantité
Sur devis exclusivement

  Catalogue produits

Mettez dans votre panier vos produits, pour une demande de devis précis et personnalisé.

  Un devis personnalisé

Recevez sous 2 heures un devis personnalisé par nos équipes avec les meilleurs prix du moment.

  Livraison

nous planifions la livraison dans les meilleurs délais sous environ 48H

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
APC
8245746

Fiche technique

Fréquence d'entrée AC
50 - 60 Hz
Poids du paquet
14,7 kg
Hauteur du colis
1980 mm
Profondeur du colis
132 mm
Largeur du colis
262 mm
Empreinte carbone
21687,02
Poids
11,7 kg
Montage
verticale
Profondeur
75 mm
Largeur
56 mm
Connexion en guirlande
Oui
Hauteur
1826 mm
Intensité (max.)
60 A
Certification
CSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1
Bouton marche/arrêt intégré
Non
Utilisation maximale de courant par phase
48 A
Courant d'entrée maximum par phase
60 A
Capacité d'alimentation/charge
34600 VA
Tension de sortie
240 V
Tension nominale de sortie
240 V
Prise mâle
IEC 60309
Taux d'humidité relative (stockage)
5 - 95%
Tension nominale à l'entrée
415 V
Taux d'humidité de fonctionnement
5 - 95%
Types de sortie AC
Coupleur C13, Coupleur C15, Coupleur C19, Coupleur C21
Altitude de non fonctionnement
0 - 15240 m
Température hors fonctionnement
-25 - 65 °C
Altitude de fonctionnement
0 - 3048 m
Nombre de prises en sortie
48 sortie(s) CA
Température d'opération
-5 - 60 °C
Types de PDU
Commutable
Écran
LCD
Couleur
Noir
Capacité du rack
0U
Type
Monophasé
Single-phase

Références spécifiques

EAN-13
731304439103