APC APDU10450SM unité de distribution d'énergie 42 sortie(s) CA 0U Noir
search
  • APC APDU10450SM unité de distribution d'énergie 42 sortie(s) CA 0U Noir
  • APC APDU10450SM unité de distribution d'énergie 42 sortie(s) CA 0U Noir
  • APC APDU10450SM unité de distribution d'énergie 42 sortie(s) CA 0U Noir
  • APC APDU10450SM unité de distribution d'énergie 42 sortie(s) CA 0U Noir
  • APC APDU10450SM unité de distribution d'énergie 42 sortie(s) CA 0U Noir
  • APC APDU10450SM unité de distribution d'énergie 42 sortie(s) CA 0U Noir
  • APC APDU10450SM unité de distribution d'énergie 42 sortie(s) CA 0U Noir
  • APC APDU10450SM unité de distribution d'énergie 42 sortie(s) CA 0U Noir

APC APDU10450SM unité de distribution d'énergie 42 sortie(s) CA 0U Noir

5 225,00 €
TTC
APC APDU10450SM, Avec mesure en ligne, 0U, Triphasé, verticale, Noir, 42 sortie(s) CA
Quantité
Sur devis exclusivement

  Catalogue produits

Mettez dans votre panier vos produits, pour une demande de devis précis et personnalisé.

  Un devis personnalisé

Recevez sous 2 heures un devis personnalisé par nos équipes avec les meilleurs prix du moment.

  Livraison

nous planifions la livraison dans les meilleurs délais sous environ 48H

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
APC
8245747

Fiche technique

Fréquence d'entrée AC
50 - 60 Hz
Poids du paquet
15,7 kg
Hauteur du colis
1980 mm
Profondeur du colis
262 mm
Largeur du colis
132 mm
Température d'opération
-5 - 60 °C
23 - 140 °F
Empreinte carbone
24171,76
Poids
12,7 kg
Montage
verticale
Profondeur
7,5 mm
Intensité (max.)
60 A
Largeur
5,6 mm
Nombre de phases
3
Hauteur
182,6 mm
Certification
UL 62368-1
CSA C22.2 No 62368-1
FCC part 15 subpart B
CE
EN 62368-1
Taux d'humidité relative (stockage)
5 - 95%
Taux d'humidité de fonctionnement
5 - 95%
Tension nominale à l'entrée
200 - 240, 346 - 415 V
Types de sortie AC
Coupleur C13, Coupleur C15, Coupleur C19, Coupleur C21
Température hors fonctionnement
-25 - 65 °C
Altitude de non fonctionnement
0 - 15240 m
Altitude de fonctionnement
0 - 3048 m
Nombre de prises en sortie
42 sortie(s) CA
Types de PDU
Avec mesure en ligne
Longueur de câble
1,8 m
Couleur
Noir
Capacité du rack
0U
Type
Three-phase
Triphasé

Références spécifiques

EAN-13
731304439752